Tssc And Kvm Kit; Visually Inspecting Indicator And Fault Leds - IBM System Storage TS7650G 3958 DD4 Installation Roadmap Manual

For the gateway
Table of Contents

Advertisement

|
|
|
|
|
| |
| |
| |
| |
| |
| |
| |
| |
| |
|
|
|

TSSC and KVM kit

|
|
|

Visually inspecting indicator and fault LEDs

v In a clustered configuration, turn on the bottom server (Server A) first, wait a
few moments and then turn on the top server (Server B).
v During the boot cycle, the ProtecTIER file systems are mounted. If the message:
Running... displays, press <enter> to proceed to the login prompt.
6
1
5
Figure 29. Server operator panel
Table 27. Server operator panel
Callout
1
2
3
4
5
6
7
For more detailed information, refer to the IBM System x3850 X5 and x3950 X5
Types 7145 and 7146 Installation and User's Guide that was provided with the server.
Use this section to turn on the TSSC and KVM.
About this task
To turn on the TSSC, press the white power button on the front of the TSSC.
If you have a KVM, press the black power button on the monitor in the KVM kit.
Visually inspect the indicator and fault LEDs on all TS7650G servers and
recommended hardware components:
v Validate that all links on the internal Ethernet network indicate 1000 Mbps,
except for the Ethernet connection to the WTI network power switch, which
indicates 100 Mbps. All connections, except the connection to the WTI network
power switch, must be at 1000 Mbps for the cluster configuration to work.
v If all link-up indicators and fault LEDs show normal operation, close the front
and rear doors of the frames.
1
7
2
3
4
description
Information LED
System-error LED
Locator button/locator LED
Ethernet port activity LEDs
Power control button cover
Power control button/power-on LED
Ethernet icon LED
Chapter 4. Installing the TS7650G hardware