Table 5. Responsibilities matrix (continued)
Task
Meet the preinstallation requirements outlined in the IBM System Storage
TS7600 with ProtecTIER Introduction and Planning Guide for the TS7650G
(3958 DD4), IBM form number GC53–1152
Complete the worksheets provided in the IBM System Storage TS7600 with
ProtecTIER Introduction and Planning Guide for the TS7650G (3958 DD4),
IBM form number GC53–1152. For convenience, blank copies of the
worksheets are included as appendices in this document.
|
Purchase, install, and configure (if necessary), all hardware components
|
not included in the purchase of the gateway. Use the IBM System Storage
| | |
|
TS7650 - Best Practices Guide for ProtecTIER v. 2.5 and TS7650G (Gateway)
|
Attached Storage for reference.
Confirm that an existing TSSC that is being used with the TS7650G has
Feature Code 2719.
Note: Unless an existing TSSC resides in the server frame and is used in
conjunction with a KVM switch, the customer must provide a USB
keyboard and graphics-capable monitor for server configuration.
Ensure that a separate USB keyboard and graphics-capable monitor are
available for use during installation.
Oversee project management for the installation and integration of the
engagement.
Oversee change management and process control for the installation.
Coordinate and schedule IBM resources for customer installations, and act
as a focal point of contact for coordination of installation services.
Schedule and facilitate planning and solution assurance conference calls.
Create and document the installation service process.
Install the TS7650G hardware components purchased with the gateway,
into the server and disk storage frames.
|
Label and connect power, Ethernet, and fibre channel cables, including
| | |
|
OST front-end cables, as necessary and applicable.
Connect the TS7650G to the customer's local area network and replication
network, if applicable.
Power-up the system.
Verify accuracy of hardware installation and cabling. Perform visual
check of fault indicator LEDs.
Configure the TSSC for use with the TS7650G.
Configure the RAS package on the servers.
Test Call Home on the servers.
|
Configure ProtecTIER on the stand-alone server or Server A in a cluster,
| | |
|
including OST if applicable, and create the file system.
Install ProtecTIER Replication Manager on one of the ProtecTIER servers
being used for replication, if applicable.
Install ProtecTIER Manager on the TSSC or ProtecTIER Manager
workstation, register each server as a new ProtecTIER node, and create
the repository.
Add the second server (Server B) to the ProtecTIER cluster, if applicable.
Trained
ProtecTIER
Customer
specialist and/or
LBS
"
"
"
"
"
"
"
"
"
"
"
"
"
"
Chapter 4. Installing the TS7650G hardware
SSRs
"
"
"
"
"
"
"
"
19