Chapter 7. RAS verification

Verifying the systems attached to the TSSC

|
|
|
|
© Copyright IBM Corp. 2008, 2010
Use the following procedures to perform RAS verification and validation, and to
test Call Home.
Procedure
1. If you are not already logged into the TSSC do so now, with the username
service and the password service.
2. Right-click on the TSSC's blue desktop.
The IBM TS3000 System Console menu displays.
3. System Console Actions → Console Configuration Utility
If prompted for a username and password, enter service in both fields.
The Console Configuration Utility starts and the Console Configuation screen
displays.
4. Click Attached Systems.
The Attached Systems screen displays with the newly-installed systems shown.
See Figure 36.
Note: If the new system does not display in the Attached Systems list
automatically, click Refresh. If it does not display, you can attempt to add in
the IP address (172.31.1.xx) manually, and click Add System. If the system does
not display after these attempts, contact your next level of support.
Figure 36. Attached Systems screen