VFC 3210
11 Quick Start
11.1 Checklist before Quick Start
11.1.1 Step 1: Check application conditions
Rated ambient temperature
Derating / ambient temperature
Rated storage temperature
Rated altitude
Derating / altitude
Mounting mode
Tab. 11-1: Application conditions checklist
See also in
chapter 6.1.8 "Conditions" on page
11.1.2 Step 2: Check mounting conditions
Converter mounting direction
Minimum top space
Minimum bottom space
One converter is arranged above another
Mounting screws
Tab. 11-2: Mounting conditions checklist
See also in
chapter 7.1 "Installation Conditions" on page
11.1.3 Step 3: Check the wiring
Mains connection
Motor connection
Grounding
Shielding
Power cables
Control terminals connection
Control cables
EMC
Switches
Load
Tab. 11-3: Wiring checklist
DOK-RCON04-VFC3210****-IT01-EN-P
-10...40 ℃
1.5 % / 1 °C (40...50 °C)
-20...60 ℃
≤ 1,000 m
1 % / 100 m (1,000...2,000 m)
Wall mounting
21.
Vertical
d
= 150 mm
top
d
= 150 mm
bot
Air guide available is required in between
2 x M4 or 4 x M4, no loose screws
Connect L1, L2, (L3) of converter to mains accordingly
Connect U, V, W of converter to motor accordingly
Must be securely connected
Must be securely connected
Must observe
chapter 8.1 "Wiring Diagram" on page 31
Must be securely connected
Must observe
chapter 8.2.2 "Control Cables" on page 35
Must observe
chapter 9 "Electromagnetic Compatibility
(EMC)" on page 44
Must be switched off
Must be disconnected
Bosch Rexroth AG
Quick Start
26.
69/253