10.6 Digit Shifting Function for Modification of Parameter Values
VFC 3210 also provides the digit shifting function for modification of parameter
values. To activate this function, press '<Func> + <▲>' or '<Func> + <▼>' once
when the frequency converter is displaying a certain parameter value. After this
action, the unit digit of the value blinks.
To select the digit for modification, press the following button combinations.
Pressing '<Func> + <▲>' once: the blinking digit is shifted one digit leftwards.
●
Pressing '<Func> + <▼>' once: the blinking digit is shifted one digit right-
●
wards.
Example: [E0.07] = 35.40. The frequency is now displaying '35.40'.
If the value '35.40' needs to be modified to be 15.40, execute the following
steps.
Step 1: Pressing '<Func> + <▲>' or '<Func> + <▼>' once to activate the digit
●
function. '35.40' is displayed with the unit digit '5' blinking.
Step 2: Pressing '<Func> + <▲>' again to shift the blinking digit leftwards.
●
'35.40' is displayed with tens digit '3' blinking.
Step 3: Pressing <▼> twice to change the tens digit '3' to be '1'. '15.40' is dis-
●
played with tens digit '1' blinking.
Step 4: Pressing <Set> to save the modified parameter value '15.40'. The dis-
●
play returns back to an upper menu level to show the next parameter with
'E0.08' displayed.
The digit shifting function is only available for parameters with
●
values and unavailable for parameter with options.
Press <Func> button and do not release it until <▲> or <▼> button
●
has been pressed.
Press <▲> or <▼> button within 2 s if <Func> button is pressed.
●
Press <Func> button over 2 s without pressing any other button to
●
cancel the uncompleted setting with button combinations.
68/253
VFC 3210
DOK-RCON04-VFC3210****-IT01-EN-P