Bosch Rexroth VFC 3210 Operating Instructions Manual page 150

Frequency converter
Hide thumbs Also See for Rexroth VFC 3210:
Table of Contents

Advertisement

Bosch Rexroth AG
Functions and Parameters
– 'Jog command' active: Accelerate to [E0.60] 'Jog frequency' according to
[E0.61] 'Jog acceleration time'.
– 'Jog command' inactive: Decelerate to prior 'Setting frequency' accord-
ing to [E0.27] 'Deceleration time'.
Fig. 12-25: Jog acceleration / deceleration time
Forward jog
Active
Active
Inactive
Tab. 12-6: Jog configuration
If the jog command direction does not match the current jog running
direction, the converter will stop according to [E0.50] 'Stop mode'.
122/253
Reverse jog
Active
Inactive
Active
VFC 3210
Running status
Stop
Jog forward
Jog reverse
DOK-RCON04-VFC3210****-IT01-EN-P

Advertisement

Table of Contents
loading

Table of Contents