12.2.4 Analog Output Configuration

Step 1: Set AO output mode
Code
Name
E2.26 AO1 output setting
AO1 value in percentage
E2.28
from
extension
fieldbus communication
E2.40 Rated voltage
0: Output frequency
Represents the actual output frequency between 0.00...[E0.08] Hz.
1: Setting frequency
Represents the setting frequency between 0.00...[E0.08] Hz.
2: Output current
Represents the 0...2 x [rated current].
4: Output voltage
Represents 0...1.2 x [rated voltage], which is defined by parameter E2.40.
5: Output power, represents 0...1.2 x [rated power]
6: Analog input, represents AI1 input value
12: Parameter setting from communication
– For parameter E2.26, the relationship between the output of '12: Parame-
ter setting from communication' and the communication mode is as follow:
– For modbus mode, the output is defined by register 0x7F06. The value
range of register is 0.00 %...100.00 % (It means percentage of maximum
analog output value).
– For other fieldbus mode, the output is defined by parameter E2.28.
Step 2: Set AO1 filter time and output curve
Code
E2.27 AO1 gain
E2.50 Output curve 1 minimum
E2.51 Output curve 1 minimum value
E2.52 Output curve 1 maximum
E2.53 Output curve 1 maximum value
DOK-RCON04-VFC3210****-IT01-EN-P
Setting range
0...12
card
0.00...100.00 %
1P 200 VAC: 200...240 V
3P 400 VAC: 380...480 V
Name
Functions and Parameters
Setting range
0.0...10.00
0.0 %...[E2.52]
0.00...100.00 %
[E2.50]...100.0 %
0.00...100.00 %
Bosch Rexroth AG
Default
Min.
Attri.
0
Run
0.00
0.01
Run
220
1
Stop
380
Default
Min.
Attri.
1.00
0.01
Run
0.0
0.1
Run
0.00
0.01
Run
100.0
0.1
Run
100.00
0.01
Run
85/253