VLT® FC 100 LonWorks
9.4.2. Input variables (nvi)
Variable Function
Start/Stop
Control word
Reset fault
Reference [%]
Reference [Hz]
CL Setpoint 1
CL Setpoint 2
CL Setpoint 3
Bus feedback 1
Bus feedback 2
Bus feedback 3
Digital/relay outputs
Analog output (42)
Analog output (X30/8) nvi101AnOut1
Analog output (X42/7) nvi109AnOut1
Analog output (X42/9) nvi109AnOut2
Analog output
(X42/11)
Setting of RTC
ECB option Mode
ECB By-pass activa-
tion
Parameter access
command
Drive speed setpoint
Standard Node Object nviRequest
9.4.3. Configuration properties (nci)
Max. motor speed [%]
Min. motor speed [%]
Nom. motor speed [RPM]
Nom. motor frequency [Hz] nciNmlFreq
Min. ramp-up time [s]
Min. ramp-down time [s]
Heartbeat time [s]
Max Send Time (Heartbeat) nciMaxStsSendT
Min Send Time (Inhibit timer) nciMinSendT
Variable Name
nviStartStop
nviControlword
nviResetFaut
nviRefPcnt
nviRefHz
nviSetpoint1
nviSetpoint2
nviSetpoint3
nviFeedback1
nviFeedback2
nviFeedback3
nviDigiOutput
nviAnOut1
nvi109AnOut3
nviTimeStamp
nviECBMode
nviECBActivation SNVT_switch
nviParamRequest UNVT_param_request FC VSD
nviDrvSpeedStpt SNVT_switch
Variable function
Variable name
nciMaxSpeed
nciMinSpeed
nciNmlSpeed
nciRampUpTime
nciRampDownTime SNVT_time_sec
nciSndHrtBt
MG.11.E1.02 - VLT
®
is a registered Danfoss trademark
SNVT type
Profile
SNVT_switch
FC VSD
SNVT_state
FC VSD
SNVT_switch
FC VSD
SNVT_lev_percent
FC VSD
SNVT_freq_hz
FC VSD
SNVT_lev_percent
FC VSD
SNVT_lev_percent
FC VSD
SNVT_lev_percent
FC VSD
SNVT_lev_percent
FC VSD
SNVT_lev_percent
FC VSD
SNVT_lev_percent
FC VSD
SNVT_state
FC VSD
SNVT_lev_percent
FC VSD
SNVT_lev_percent
FC VSD
SNVT_lev_percent
FC VSD
SNVT_lev_percent
FC VSD
SNVT_lev_percent
FC VSD
SNVT_time_stamp
FC VSD
SNVT_state
FC VSD
FC VSD
VSD 6010 CTW / Reference
SNVT_obj_request
Node obj.
SNVT type
SNVT_lev_percent VSD 6010
SNVT_lev_percent VSD 6010
SNVT_rpm
SNVT_freq_hz
SNVT_time_sec
SNVT_time_sec
SNVT_elapsed_tm Node obj.
SNVT_elapsed_tm
9. Troubleshooting
FC 100 par.
CTW/reference
CTW
CTW
Reference
Reference
20-21
20-22
20-23
8-94
8-95
8-96
5-90
6-53
6-63
26-43
26-53
26-63
0-70
31-00
31-19
-
-
FC 100
Profile
parame-
ter
4-13
4-11
VSD 6010
1-25
VSD 6010
1-23
VSD 6010
3-41
VSD 6010
3-42
VSD 6010
-
-
Virtual
-
obj.
67
9

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VLT FC 100 and is the answer not in the manual?

Questions and answers

Table of Contents