NEC Express5800 Series Maintenance Manual page 74

Hide thumbs Also See for Express5800 Series:
Table of Contents

Advertisement

Chapter 1 Maintenance
[?]
NEC ESMPRO Manager:
 For details of NEC ESMPRO Manager, see "NEC ESMPRO Manager Installation Guide" in
EXPRESSBUILDER or its help.
Supplementary explanation about Information of server state/constitution of NEC ESMPRO Manager
Status Color after Mounting a Hard Disk Drive
 When creating a new mirror, the status of SCSI Enclosure and SCSI Slot of Information of
server state/constitution will continue to change frequently after you mount a hard disk until the
mirror is completed. During this process, the status color may turn to abnormal, but when the
mirror is created successfully, it will return normal.
CPU Information
 The CPU information can be viewed by selecting System – CPU in the Information of server
state/constitution screen.
 If you select CPU Module – CPU in the ft System tree, unknown or incorrect information appears
in some information items.
* Selecting CPU in the ft System tree may fail to confirm the correct information.
Change of hardware configuration
 If you dynamically change the configuration of the CPU or PCI module (IO module), Information of
server state/constitution tree may not be displayed correctly. In such a case, wait for about 5
minutes, open Information of server state/constitution again.
Display immediately after system startup
 If you open Information of server state/constitution immediately after the system starts up, the
tree or the state may not be displayed correctly due to high load of the system. In about 20
minutes after the system startup, open Information of server state/constitution again.
Display when the PCI module (IO module) is running in the simplex mode.
 When only the PCI modules (IO modules) is running in the simplex mode (non-duplexed mode),
the Information of server state/constitution cannot display the status of the SCSI Enclosure
and Mirror Disk correctly. To check if the duplex mode is changed to the simplex mode, check the
event log or AlertViewer log, or the status color of the PCI module by the Information of server
state/constitution.
SCSI Status while PCI module is Starting or being Stopped:
 While the PCI module is starting or being stopped, the status of SCSI Enclosure, SCSI Slot, and
Mirror Disk in Information of server state/constitution may become unstable, and incorrect
status may be displayed temporarily. When Starting or Stopping of module completes, the status
will be displayed correctly.
Display of an Unmounted Sensor
 An unmounted sensor is indicated as "Unknown" on Information of server state/constitution.
Ex: Information of server state/constitution - Enclosure - Temperature
74
Temperature information
Location:
DIMM2 Temp#0
Temperature:
Unknown
Threshold:
Disabled
Status:
Unknown
Express5800/R320e-E4, R320e-M4 Maintenance Guide (Linux)
8. Troubleshooting

Advertisement

Table of Contents
loading

This manual is also suitable for:

Exp320sExpress5800/r320e-e4Express5800/r320e-m4Exp320r

Table of Contents