4. How to programme the frequency converter

4.1. How to programme

4.1.1. Parameter Set-Up
Group
0-
1-
2-
3-
4-
5-
6-
8-
9-
10-
11-
13-
14-
15-
16-
18-
20-
21-
22-
23-
25-
26-
27-
29-
31-
Table 4.1: Parameter Groups
Parameter descriptions and selections are displayed on the graphic (GLCP) or numeric (NLCP) in
the display area. (See Section 5 for details.) Access the parameters by pressing the [Quick
Menu] or [Main Menu] key on the control panel. The quick menu is used primarily for commis-
sioning the unit at start-up by providing those parameters necessary to start operation. The main
menu provides access to all parameters for detailed application programming.
All digital input/output and analog input/output terminals are multifunctional. All terminals have
factory default functions suitable for the majority of water applications but if other special func-
tions are required, they must be programmed in parameter group 5 or 6.
4.1.2. Quick Menu Mode
The GLCP provides access to all parameters listed under the Quick Menus. The NLCP only provides
access to the Quick Setup parameters. To set parameters using the [Quick Menu] button:
Pressing [Quick Menu] the list indicates the different areas contained in the Quick menu.
Title
Function
Operation / Display
Parameters related to the fundamental functions of the frequency con-
verter, function of the LCP buttons and configuration of the LCP display.
Load / Motor
Parameter group for motor settings.

Brakes

Parameter group for setting brake features in the frequency converter.

Reference / Ramps

Parameters for reference handling, definitions of limitations, and con-
figuration of the reaction of the frequency converter to changes.

Limits / Warnings

Parameter group for configuring limits and warnings.
Digital In/Out
Parameter group for configuring the digital inputs and outputs.
Analog In/Out
Parameter group for configuration of the analog inputs and outputs.
Communication and Options
Parameter group for configuring communications and options.
Profibus
Parameter group for Profibus-specific parameters.
DeviceNet Fieldbus
Parameter group for DeviceNet-specific parameters.
LonWorks
Parameter group for LonWorks parameters
Smart Logic
Parameter group for Smart Logic Control
Special Functions
Parameter group for configuring special frequency converter functions.
Drive Information
Parameter group containing frequency converter information such as
operating data, hardware configuration and software versions.
Data Readouts
Parameter group for data read-outs, e.g. actual references, voltages,
control, alarm, warning and status words.
Info and Readouts
This parameter group contains the last 10 Preventive Maintenance logs.
Drive Closed Loop
This parameter group is used for configuring the closed loop PID Con-
troller that controls the output frequency of the unit.
Extended Closed Loop
Parameters for configuring the three Extended Closed Loop PID Con-
trollers.
Application Functions
These parameters monitor water applications.
Time-based Functions
These parameters are for actions needed to be performed on a daily or
weekly basis, e.g. different references for working hours/non-working
hours.
Basic Cascade Controller Func-
Parameters for configuring the Basic Cascade Controller for sequence
tions
control of multiple pumps.
Analog I/0 Option MCB 109
Parameters for configuring the Analog I/0 Option MCB 109.
Extended Cascade Control
Parameters for configuring the Extended Cascade Control.
Water Application Functions
Parameters for setting water specific functions.
Bypass Option
Parameters for configuring the Bypass Option
®
MG.20.P1.02 - VLT
is a registered Danfoss trademark
4. How to programme the frequency converter