8.5 Configuration control
Control data record
The table below shows the structure of a control data record with explanations of the
individual elements. The control data record can also be read back.
Table 8- 2
Byte
0
1
2
3
4
5
...
28
...
96
Structure of the simplified control data record V1.0
Element
Code
Block length
4 +
maximum slot
Block ID
196
Version
1
Version
0
Slot 1 of the station
Slot assignment in the
master
station option
Slot 2 of the station
Slot assignment in the
master
station option
...
...
Slot 25 of station mas-
Slot assignment
ter
...
...
Explanation
Header
Control element
Contains the information on which
module is inserted in which slot.
The value that you need to enter in the
corresponding byte depends on the
following rule:
If the module is included in the
station option, enter the slot num-
ber of the module from the station
master.
If the module does not exist in the
station option, enter 0.
...