YASKAWA A1000 Series Quick Start Manual page 284

High performance vector control drive
Hide thumbs Also See for A1000 Series:
Table of Contents

Advertisement

B.6 F: Option Settings
No.
(Addr.
Name
Hex)
F6-49
BACnet Device Object
(02FF)
Identifier 1
F6-50
DeviceNet MAC
(03C1)
Address
F6-51
DeviceNet
(03C2)
Communication Speed
F6-52
DeviceNet PCA Setting PCA Selection
(03C3)
F6-53
DeviceNet PPA Setting PPA Selection
(03C4)
F6-54
DeviceNet Idle Mode
(03C5)
Fault Detection
F6-55
DeviceNet Baud Rate
(03C6)
Monitor
F6-56
DeviceNet Speed
(03D7)
Scaling
F6-57
DeviceNet Current
(03D8)
Scaling
F6-58
DeviceNet Torque
(03D9)
Scaling
F6-59
DeviceNet Power
(03DA)
Scaling
F6-60
DeviceNet Voltage
(03DB)
Scaling
F6-61
DeviceNet Time Scaling Time Scale
(03DC)
F6-62
DeviceNet Heartbeat
(03DD)
Interval
F6-63
DeviceNet Network
(03DE)
MAC ID
F6-64 to
F6-71
Reserved
(03DF to
03C8)
F6-72
PowerLink Node
(081B)
Address
<1> Parameter setting value is not reset to the default value when the drive is initialized.
<2> Values shown are for the MECHATROLINK-II option (SI-T3). Values for MECHATROLINK-III option (SI-ET3) are: Min: 03, Max.: EF
<3> Values shown are for the MECHATROLINK-II option (SI-T3). Values for MECHATROLINK-III option (SI-ET3) are: 0: 64-byte, 1: 32-byte
284
LCD Display
Sets the most significant word for BACnet.
BAC Dev Obj Id 1
Selects the drive MAC address.
DN MAC Address
DN Baud Rate
0: 125 kbps
0: 125 kbps
1: 250 kbps
1: 250 kbps
2: 500 kbps
2: 500 kbps
3: Adjustable from network
3: Set from Network
4: Detect automatically
4: Auto Detect
Sets the format of the data set from the DeviceNet master to the
drive.
Sets the format of the data set from the drive to the DeviceNet
master.
DN Idle Flt Det
0: Enabled
0: Stop
1: Disabled, no fault detection
1: Ignore
2: Vendor Specific
2: Vendor Specific
3: Forward
3: Run Fwd
4: Reverse
4: Run Rev
DN BAUD RATE
Verifies the baud rate running on the network.
MEM
0: 125 kbps
0: 125 kbps
1: 250 kbps
1: 250 kbps
2: 500 kbps
2: 500 kbps
Sets the scaling factor for the speed monitor in DeviceNet.
Speed Scale
Sets the scaling factor for the output current monitor in
Current Scale
DeviceNet.
Sets the scaling factor for the torque monitor in DeviceNet.
Torque Scale
Sets the scaling factor for the power monitor in DeviceNet.
Power Scale
Sets the scaling factor for the voltage monitor in DeviceNet.
Voltage Scale
Sets the scaling factor for the time monitor in DeviceNet.
Sets the heartbeat interval for DeviceNet communications.
DN Heart Beat
Saves and monitors settings 0 to 63 of F6-50 (DeviceNet MAC
DN MAC ID MEM
Address).
Reserved for Dynamic I/O Assembly Parameters.
PowerLink NodeID
Reserved.
YASKAWA ELECTRIC TOEP C710616 41G YASKAWA AC Drive - A1000 Quick Start Guide
Description
Values
Page
Default: 0
Min.: 0
Max.: 3F
Default: 64
Min.: 0
Max.: 64
Default: 4
Range: 0 to 4
Default: 21
Min.: 0
Max.: 255
Default: 71
Min.: 0
Max.: 255
Default: 0
Range: 0 to 4
Default: 0
Range: 0 to 2
Default: 0
Min.: -15
Max.: 15
Default: 0
Min.: -15
Max.: 15
Default: 0
Min.: -15
Max.: 15
Default: 0
Min.: -15
Max.: 15
Default: 0
Min.: -15
Max.: 15
Default: 0
Min.: -15
Max.: 15
Default: 0
Min.: 0
Max.: 10
Default: 63
Min.: 0
Max.: 63