PROBLEM
1. No product is being
dispensed.
2. Insufficient mix in the
freezing cylinder.
Model 8756

Troubleshooting Guide

PROBABLE CAUSE
a. Low on mix. The MIX
OUT light is on.
b. The power switch is in the
OFF position.
c. The beater motor is out on
reset.
d. Insufficient mix in the
freezing cylinder.
e. Restriction in the door
spout.
f. Machine is unplugged.
g. Circuit breaker is off or the
fuse is blown.
h. The mix probe was not
installed properly or was
damaged.
i. The beater assembly is
rotating counterclockwise.
a. Suction line is not fully
submerged in the mix.
b. Improper seal of suction
line to the mix inlet fitting.
c. Worn or defective check
bands or o-rings in air/mix
pump assembly.
35
REMEDY
a. Add mix to the mix tank
and press the AUTO key.
b. Place the power switch in
the ON position and press
the AUTO key.
c. Reset the freezer.
d. Refer to problem #2.
e. Disassemble and clean
the freezer. Never put
objects or fingers in the
door spout.
f. Plug machine into the wall
receptacle.
g. Turn the breaker on or
replace the fuse.
h. Check the mix probe
installation.
i. Contact a service
technician to correct the
rotation to clockwise.
a. Arrange the suction line
so the weighted end is
fully submerged.
b. Remove the suction line
from the mix inlet fitting.
Place under hot running
water, allow tubing to
swell, then cool. Connect
suction line to barbed
fitting. Eventual
replacement will be
necessary.
c. Replace regularly. Never
lubricate check bands.
Troubleshooting Guide
PAGE
REF.
27
- - -
13
- - -
- - -
- - -
- - -
27
- - -
27
- - -
21 / 40