Beater Rotation; Refrigerant - Taylor 8756 Operator's Manual

Single stage pump soft serve freezer
Table of Contents

Advertisement

S
Supply cords used with this unit shall be
oil­resistant, sheathed flexible cable not
lighter than ordinary polychloroprene or oth­
er equivalent synthetic elastomer­sheathed
cord (Code designation 60245 IEC 57) in­
stalled with the proper cord anchorage to
relieve conductors from strain, including
twisting, at the terminals and protect the in­
sulation of the conductors from abrasion.
If the supply cord is damaged, it must be
replaced by an authorized Taylor service
technician in order to avoid a hazard.

Beater Rotation

Beater rotation must be clockwise as viewed
looking into the freezing cylinder.
The following procedures must be
performed by an authorized Taylor service
technician.
To correct the rotation on a three-phase unit,
interchange any two incoming power supply lines at
freezer main terminal block only.
To correct rotation on a single-phase unit, change
the leads inside the beater motor. (Follow the
diagram printed on the motor.)
Electrical connections are made directly to the
terminal block provided in the main control box.
Model 8756

Refrigerant

In consideration of our environment, Taylor
uses only HFC refrigerants. The HFC refrigerant
used in this unit is R404A. This refrigerant is
generally considered non­toxic and non­flammable,
with an Ozone Depleting Potential (ODP) of zero (0).
However, any gas under pressure is potentially
hazardous and must be handled with caution.
NEVER fill any refrigerant cylinder completely with
liquid. Filling the cylinder to approximately 80% will
allow for normal expansion.
Use only R404A refrigerant that conforms
to the AHRI standard 700 specification. The use of
any other refrigerant may expose users and
operators to unexpected safety hazards.
Refrigerant liquid sprayed onto the skin may
cause serious damage to tissue. Keep eyes and skin
protected. If refrigerant burns should occur, flush
immediately with cold water. If burns are severe,
apply ice packs and contact a physician
immediately.
Taylor reminds technicians to be cautious of
government laws regarding refrigerant recovery,
recycling, and reclaiming systems. If you have any
questions regarding these laws, please contact the
factory Service Department.
WARNING: R404A refrigerant used in
conjunction with polyolester oils is extremely
moisture absorbent. When opening a refrigeration
system, the maximum time the system is open must
not exceed 15 minutes. Cap all open tubing to
prevent humid air or water from being absorbed by
the oil.
3
131220