Important: Operator Checklist; During Cleaning And Sanitizing; Troubleshooting Bacterial Count; Regular Maintenance Checks - Taylor 8756 Operator's Manual

Single stage pump soft serve freezer
Table of Contents

Advertisement

Section 7

During Cleaning and Sanitizing

ALWAYS FOLLOW LOCAL HEALTH CODES.
Cleaning and sanitizing schedules are governed
by federal, state, or local regulatory agencies,
and must be followed accordingly. If the unit
has a "Standby mode", it must not be used in
lieu of proper cleaning and sanitizing
procedures and frequencies set forth by the
ruling health authority. The following check
points should be stressed during the cleaning
and sanitizing operations.
CLEANING AND SANITIZING MUST BE
PERFORMED DAILY.

Troubleshooting Bacterial Count

j 1. Thoroughly clean and sanitize the machine
regularly, including complete disassembly and
brush cleaning.
j 2. Use all brushes supplied for thorough
cleaning. The brushes are specially designed
to reach all mix passageways.
j 3. Use the long white bristle brush to clean the
mix feed tube which extends from the mix
reservoir to the rear of the freezing cylinder.
j 4. Use the black bristle brush to thoroughly
clean the rear shell bearing located at the rear
of the freezing cylinder. Be sure there is a
generous amount of cleaning solution on the
brush.
Model 8756

Important: Operator Checklist

j 5. Properly prepare the cleaning and sanitizing
j 6. The temperature of the mix in the mix cabinet

Regular Maintenance Checks

j 1. Replace scraper blades that are bent,
j 2. Before installing the beater, be certain that the
j 3. Check the rear shell bearing for signs of wear
j 4. Using a screwdriver and cloth towel, keep the
j 5. Dispose of o-rings and seals if they are worn,
j 6. Follow all lubricating procedures as outlined in
33
solutions. Read and follow the label directions
carefully. Too strong of a solution may
damage the parts and too weak of a solution
will not do an adequate job of cleaning or
sanitizing. Sanitize the freezing cylinder for 5
minutes.
and the walk-in cooler should be below 38_F
(3.3_C).
damaged or worn.
scraper blades are properly attached over the
pins and the beater assembly is straight.
(excessive mix leakage in the rear drip pan)
and be certain it is properly cleaned.
rear shell bearing and the female hex drive
socket clean and free of lubricant and mix
deposits.
torn, or fit too loosely, and replace with new
ones.
"Assembly".
Important: Operator Checklist