j 7. If your machine is air cooled, check the
condensers for accumulation of dirt and lint.
Dirty condensers will reduce the efficiency
and capacity of the machine. Condensers
should be cleaned monthly with a soft brush.
Never use screwdrivers or other metal probes
to clean between the fins.
Note: For machines equipped with an air
filter, it will be necessary to vacuum the filters
on a monthly schedule.
j 8. Your machine is equipped with an auxiliary
refrigeration system. Check the auxiliary
condenser for accumulation of dirt and lint.
Dirty condensers will reduce the refrigeration
capacity of the mix cabinet. Condensers must
be cleaned monthly with a soft brush. Never
use screwdrivers or other metal probes to
clean between the fins.
j 9. On water cooled units, check the water lines
for kinks or leaks. Kinks can occur when the
machine is moved back and forth for cleaning
or maintenance purposes.
Important: Operator Checklist

The Air/Mix Pump

j 1. Dispose of the o-rings, the check bands and
the pressure switch diaphragm if they are
worn, torn or fit too loosely. Replace them
with new ones.
j 2. Follow lubricating procedures carefully.
Never lubricate check bands.
j 3. Handle plastic pump parts with care to avoid
nicks and cracks.
j 4. Be sure the pressure line is securely attached
to the pressure switch.
j 5. Clean, sanitize, and lubricate the pressure
switch diaphragm daily.
j 6. Be sure the air/mix pump is properly aligned
with the face plate of the motor reducer or
severe and costly damage may occur.