Assa Abloy Sargent Profile Series Installation Instructions Manual page 14

Poe mortise lock
Hide thumbs Also See for Sargent Profile Series:
Table of Contents

Advertisement

5 – Install Gasket (for Exterior Doors)
1. Carefully remove the backing from the gasket.
2. Apply gasket to escutcheon:
• Starting in one place, press the adhesive side
of the gasket firmly against the escutcheon.
• Work around the escutcheon, pressing the sticky side
of the gasket firmly against the escutcheon edge.
• The gasket should be aligned so that all edges
of the escutcheon are covered.
3. Attach escutcheon to the door after the wires
are connected.
Note: The 43 cylinder may be used with or without a gasket.
6 – Install Outside Escutcheon and Lever Assembly
1A. For fire rated doors, feed ribbon cable with connector and ground wire from
outside of door through weatherseal gasket and fire stop plate (Fig. 6A).
Note: Install ribbon cable with cable exiting down
1B. For non-fire rated doors, feed ribbon cable with connector and ground
wire from outside of door through weatherseal gasket (if used)
and weather conduit (Fig. 6A).
Note: Install ribbon cable with cable exiting down
2.
With outside lever horizontal, locate the outside escutcheon on the door,
while directing the mounting posts through the door and lock body (Fig. 6B).
Make sure the lever spindle is properly engaged in lock.
3.
On the inside of the door, insert spindle into square hole
of mortise lock.
4.
Slide inside adapter and plate
assembly over spindle and loosely
secure with 2 through bolt
screws (#8-32 x 5/8").
Scan to see a video of this
installation step.
Install Outside Escutcheon
14
1-800-810-WIRE • www.sargentlock.com • A7764D
Antenna
(iCLASS
only)
Fig. 6A
Profile Series v.S1 PoE Mortise Lock
Gasket 82-0500
Fig. 5A
Outside of Door
Ground
Wire (E1)
Keypad
Ribbon
Cable
Mortise Lock body
and AX Connectors
Gasket
Keypad
Ribbon
Cable
Antenna
(iCLASS)
Only
Ground
Wire
(E1)
Fig. 5B
Inside of Door
Ground
Ring Terminal
JST 4-Pin
From Hinge
Reader
Cable
Antenna
(iCLASS)
Ground
Wire (E1)
Fig. 6B

Advertisement