At+Csns Single Numbering Scheme - Siemens TC37 Module At Command Reference

At command set cellular engines
Table of Contents

Advertisement

AT Command Set

4.41 AT+CSNS Single Numbering Scheme

The AT+CSNS command enables the ME to accept incoming calls when no bearer capability
information is provided with the call, e.g. single numbering scheme calls or calls originitating from
analog devices.
The command must be set before the call comes. By default, when you do not modify the settings,
all calls received without bearer element are assumed to be voice.
Please note that you can use the command if PIN authentication has been done during current
session. The setting will be automatically saved when you power down the GSM engine with
AT^SMSO.
Test command
AT+CSNS=?
Read command
AT+CSNS?
Write command
AT+CSNS=[<mode>]
Reference
GSM 07.07
TC3X_ATC_01_V04.00
Response
+CSNS: (list of supported <mode>s)
OK
Response
+CSNS: <mode>
OK
Response
Write command
OK
Parameters
<mode>:
0
Voice
2
Fax
4
Data
Note
Page 113 of 204
Each call received without bearer element is
assumed to be speech.
Each call received without bearer element is
assumed to be an incoming fax.
Each call received without bearer element is
assumed to be a data call.
Please take into account that the bearer service
parameters set with AT+CBST apply to all data
calls including those received without bearer
capability. To avoid conflicts see Chapter 4.5.
29.05.2002

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tc35 moduleTc35 terminal

Table of Contents