Digital Output Channel; I_Apci1500_Setoutputmemoryon; I_Apci1500_Setoutputmemoryoff; I_Apci1500_Set1Digitaloutputon - Addi-Data ADDINUM CPCI-1500 Technical Description

Digital inputs and outputs for the pci/compactpci bus
Hide thumbs Also See for ADDINUM CPCI-1500:
Table of Contents

Advertisement

APCI-/CPCI-1500
9.3.6

Digital output channel

1) i_APCI1500_SetOutputMemoryOn (...)

Syntax:
<Return value> = i_APCI1500_SetOutputMemoryOn
Parameters:
BYTE
Task:
Activates the digital output memory.
After calling this function, the output channels you have previously activated
with the functions "i_APCI1500_SetXDigitalOutputOn" are not reset.
You can reset them with the function "i_APCI1500_SetXDigitalOutputOff".
Return value:
0: No error
-1: Handle parameter of the board is wrong

2) i_APCI1500_SetOutputMemoryOff (...)

Syntax:
<Return value> = i_APCI1500_SetOutputMemoryOff
Parameters:
BYTE
Task:
Deactivates the digital output memory.
Return value:
0: No error
-1: Handle parameter of the board is wrong

3) i_APCI1500_Set1DigitalOutputOn (...)

Syntax:
<Return value> = i_APCI1500_Set1DigitalOutputOn
Parameters:
BYTE
BYTE
78
b_BoardHandle
b_BoardHandle
b_BoardHandle
b_Channel
Technical description
(BYTE b_BoardHandle)
Handle of the xPCI-1500
(BYTE b_BoardHandle)
Handle of the xPCI-1500
(BYTE b_BoardHandle,
BYTE b_Channel)
Handle of the xPCI-1500
Number of the output channel you want to
set (1 to 16)
Chapter 9

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ADDINUM CPCI-1500 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Addinum apci-1500