Technical description
IMPORTANT!
This function is only available for Windows 3.1 and Windows 3.11
3) i_APCI1500_SetBoardIntRoutineWin16 (..)
Syntax:
<Return value> = i_APCI1500_SetBoardIntRoutineWin16
Parameters:
- Input:
BYTE
VOID
- Output:
No output signal has occurred.
Task:
This function must be called up for each xPCI-1500 on which an interrupt
action is to be enabled. It installs one user interrupt function in all boards on
which an interrupt is to be enabled.
First calling (first board):
- the user interrupt routine is installed
- interrupts are enabled.
If you operate several boards xPCI-1500 which have to react to interrupts, call
up the function as often as you operate boards xPCI-1500. The variable
v_FunctionName is only relevant for the first calling.
From the second call of the function (next board):
- interrupts are allowed.
Interrupt
The user interrupt routine is called up by the system when an interrupt is
generated.
An interrupt is generated when:
- the counter/timer has run down
- an event is generated
- the watchdog has run down
Chapter 9
(BYTE
b_BoardHandle,
VOID
v_FunctionName (BYTE
b_BoardHandle
v_FunctionName
b_BoardHandle,
BYTE
b_InterruptMask,
BYTE
InputChannelNbr))
Handle of board xPCI-1500
Name of the user interrupt routine
APCI-/CPCI-1500
55
Need help?
Do you have a question about the ADDINUM CPCI-1500 and is the answer not in the manual?
Questions and answers