Page 1
DIN EN ISO 9001:2000 certified ADDI-DATA GmbH Dieselstraße 3 D-77833 OTTERSWEIER Technical support: +49 (0)7223 / 9493 – 0 Technical description MSX-E1701 Intelligent Ethernet counter/digital I/O module - Digital I/O - Edition: 01.02 – 04/2007...
Page 2
The user is not permitted to make changes to the product beyond the intended use, or to interfere with the product in any other way. ADDI-DATA shall not be liable for obvious printing and phrasing errors. In addition, ADDI DATA, if legally permissible, shall not be liable for personal injury or damage to materials caused by improper...
Page 3
WARNING The following risks result from improper implementation and from use of the product contrary to the regulations: ♦ Personal injury ♦ Damage to the I/0 module, PC and peripherals ♦ Pollution of the environment ♦ Protect yourself, the others and the environment! ♦...
Contents MSX-E1701: Digital I/O DEFINITION OF APPLICATION ....... 7 Intended use ..............7 Usage restrictions.............7 General description of the board ........7 Characteristics ..............7 Safety precautions ............7 1.4.1 Current sources..............7 1.4.2 Degrees of protection............7 1.4.3 Cables ...................8 1.4.4 Housing ..................8 1.4.5 Connection................8...
Page 5
Contents MSX-E1701: Digital I/O 5.3.1 LED display ................22 5.3.2 LED “Status”................23 CONNECTING THE PERIPHERAL......25 Pin assignment control signals ........25 6.1.1 Ethernet Ports ............... 25 6.1.2 Trigger/sync................26 6.1.3 Current supply ..............26 Signals of the counter and digital functions....27 SOFTWARE ............
Page 6
MSX-E1701: Digital I/O Figures Fig. 3-1: Correct handling..............10 Fig. 4-1: Dimensions ................ 11 Fig. 4-2: MSX-E1701: View from above..........12 Fig. 5-1: Use ..................15 Fig. 5-2: Clamps ................16 Fig. 5-3: Angles pointing to the outside ........... 16 Fig.
IEC 61010-1. Usage restrictions The Ethernet I/O module MSX-E1701 must not to be used as safety related part for securing emergency stop functions. The Ethernet I/O module MSX-E1701 must not be used in potentially explosive atmospheres.
Definition of Application MSX-E1701: Digital I/O 1.4.3 Cables The cables must be installed safely against mechanical load. 1.4.4 Housing The housing may not be opened. It may be opened only by persons who are authorized by ADDI-DATA. 1.4.5 Connection Please find information about cables and further accessories in a separate PDF file “Accessories table”...
MSX-E1701: Digital I/O User USER Qualification Only persons trained in electronics are entitled to perform the following works: - installation - use - maintenance Personal protection Consider the country-specific regulations about: - the prevention of accidents - electrical and mechanical installations...
Handling of the Ethernet I/O module MSX-E1701: Digital I/O HANDLING OF THE ETHERNET I/O MODULE Fig. 3-1: Correct handling - Do not touch the connectors - Hold the module only at the sides and at the bottom...
24 V 24 V MSX-E1701-24 Please observe that the protection is only reached if adequate protection caps are used (see chapter Fehler! Verweisquelle konnte nicht gefunden werden.) The counter function can be found in the corresponding manual (MSX-E1701: Incremental counter)
Technical data MSX-E1701: Digital I/O Fig. 4-2: MSX-E1701: View from above Accessories See link in the bookmarks „Accessories table” Limit values Max altitude: ..........2000 m Operating temperature: ......0 to 60°C (with forced ventilation) Relative humidity: ........30 to 99% non condensing Storage temperature:........
MSX-E1701: Digital I/O Technical data Optical isolation: ........1000 V Cable length: ..........150 m (max. at CAT5E UTP) Bandwidth: ..........10 Mbps (auto-negotiation) 100 Mbps (auto-negotiation) Protocol: .............10 Base-T according to IEEE802.3 100 Base-TX according to IEEE802.3 MAC-address: ..........00:0F:6C:##:##:## (unique for each device) 4.3.2...
Technical data MSX-E1701: Digital I/O : 0 V/0 mA (typical) (min.) 4.3.5 Digital outputs Number of outputs:........16 (2 per female connector) Optical isolation: ........1000 V (through opto-coupler) Output type: ..........High Side (load against mass acc. to IEC 1131-2) Nominal voltage: ........
Ethernet I/O module to a DIN rail. WARNING! Should you have already mounted the MSX-E1701 and want to transport it in a switch cabinet or in other systems, do ensure that there is sufficient transportation lock. The MSX-E1701 could fall e.g.
MSX-E1701: Digital I/O Fig. 5-2: Clamps ♦ Attach the Ethernet I/O module to the DIN rail by placing the clamp with the springs under the rail ♦ Lift the Ethernet I/O module until the upper part of the clamp locks on the rail 5.1.2...
MSX-E1701: Digital I/O Fig. 5-5: Screws and seals ♦ Put the seal into the opening ♦ Put the angle on the seal ♦ Fasten the angle with a short screw from the mounting set Fig. 5-6: Angle mounting After having attached the angles to the Ethernet I/O module, you can attach the...
MSX-E1701: Digital I/O Connecting the components ♦ Discharge yourself ♦ Take the Ethernet I/O module out of its protective pack 5.2.1 Connecting the digital functions ♦ Select one or more plugs for digital functions CH0 – CH15 = Digital plugs Fig.
MSX-E1701: Digital I/O 5.2.2 Connecting Ethernet ports ♦ Plug the Ethernet cable in Ethernet port 0 Fig. 5-8: Connecting Ethernet ports 5.2.3 Connecting trigger and synchro signals ♦ Plug the cable into the plug Trigger/Sync In Fig. 5-9: Connecting trigger and synchro signals...
MSX-E1701: Digital I/O 5.2.4 Connecting to the current supply ♦ Plug the cable into the input (24 VDC In) Fig. 5-10: Connecting the current supply Connecting several Ethernet I/O modules You can connect several Ethernet I/O modules. Hereto please observe the following steps: ♦...
MSX-E1701: Digital I/O LED display 5.4.1 Overview Fig. 5-12: LEDs: Current supply, Ethernet and Status Description Lights green Current supply OK Power On Blinks yellow Ethernet cable connected to Port 0 Port 0 ACT/Link Blinks yellow Ethernet cable connected to Port 1...
MSX-E1701: Digital I/O 5.4.2 LED “Status” The table below contains further information about the LED “Status”. Table 5-1: LED “Status” Display Meaning Possible cause Lights red Error during Hardware error (e.g. - Contact us for reparation or booting RAM) exchange...
Page 24
MSX-E1701: Digital I/O Display Meaning Possible cause Blinks Data acquisition is - The Flash memory is not - Check your IP address yellow/green possible but some working correctly - Contact us for reparation or parts are not - A wrong IP address has exchange working correctly.
This chapter contains the connector pin assignment of the control signals (see chapter 6.1) and of the function signals (see chapter 6.2). Pin assignment control signals Fig. 6-1: Control signals MSX-E1701 6.1.1 Ethernet Ports Table 6-1: Pin assignment: Ethernet Port 0 and Port 1...
MSX-E1701: Digital I/O Connecting the peripheral Signals of the counter and digital functions Table 6-4: Pin assignment of the digital I/O Pin No. Female connector, Cable color 5-pin, M12 24 V Brown Digital I/O (2n+1)* White Ground Blue Digital I/O (2n)*...
> to send commands (acquisition initialisation, etc.) Data server (TCP socket) > to obtain the values of the acquisition MSX-E1701 server access information: SOAP server: Port number 5555 Data server: Port number 8989 7.1.2 SOAP: General definition What is SOAP? SOAP (originally Simple Object Access Protocol) is a protocol with which data can be exchanged between systems, and Remote Procedure Calls can be executed.
MSX-E1701: Digital I/O Software What is a socket? A socket is a bidirectional software interface to interprocess (IPC) or network communication. Sockets are a standardized interface (API) between the network-protocol- implementation of the operating system and the actual application software.
♦ Install ADDIPACK (is on CD1 “standard drivers”) After this, continue with the module registration as follows: Inserting the module To use a module you should insert it firstly in ADDIREG. ♦ Select „MSX-E1701” when clicking on „Insert“ in the ADDIREG-main window (see Fig. 7-6)
MSX-E1701: Digital I/O Software After this the following window will be displayed: Fig. 7-2: Board type list ♦ Click on OK. After this the following window appears: Fig. 7-3: Settings ♦ Select the network card under „Ethernet interface“ Make sure that you have selected the network card to which the Ethernet I/O module is connected.
Software MSX-E1701: Digital I/O ♦ Enter the serial number of the module ♦ Click on „Start Scan“ Depending on the firewall-settings of your PC, it is possible that a Windows- warning will be displayed. ♦ Click on “Nicht mehr blocken” (don’t block) to start also in this case the scan Now the scan will be started.
MSX-E1701: Digital I/O Software Fig. 7-6: ADDIREG main window (example) ♦ Click on „Set“ and then on „Save“ Now the Ethernet I/O module will be integrated in ADDIPACK. Starting the ADDevice Managers ♦ Click on „Edit“ and then on „ADDIDriver board manager“...
Software MSX-E1701: Digital I/O Further columns: The program distinguishes between the resources (Digital/Resistance/Pressure/Transducer, ...) of the virtual module (V, software) and the real module (R, module). The following parameters are listed Module number, Number of resources Index: The first index line represents the number of the first resource (left: virtual resource - right: real board) The second index line represents the number of the last resource (left: virtual resource - right: real board).
MSX-E1701: Digital I/O Software Fig. 7-8: Board clear/insert If you need more information about the operation of the Ethernet I/O module click on “More information”. The ADDevice Manager will be started. 7.2.2 Questions and software downloads on the web Do not hesitate to e-mail us your questions. We will be pleased to support you.
MSX-E1701: Digital I/O Software 7.2.3 Standard software a) Software functions ADDIPACK supports the following functions for the Ethernet I/O module MSX-E1701. Table 7-1: Supported software functions Functionality Function name i_ADDIDATA_OpenWin32Driver Common i_ADDIDATA_GetCurrentDriverHandle functions i_ADDIDATA_GetDriverVersion b_ADDIDATA_CloseWin32Driver b_ADDIDATA_SetFunctionalityIntRoutineWin32 Interrupt b_ADDIDATA_TestInterrupt b_ADDIDATA_ResetFunctionalityIntRoutine i_ADDIDATA_GetLastError...
MSX-E1701: Digital I/O Software b) Software samples Table 7-2: Supported software samples for the Ethernet I/O module MSX-E1701 Functionality Sample Description number SAMPLE00 Get the selected digital input information Digital SAMPLE01 Read 1 digital input inputs SAMPLE02 Read 2 digital inputs...
Software MSX-E1701: Digital I/O Webserver For a more comfortable management we offer you an additional webserver. You access the webserver as follows: First enter the IP address of the module in a webbrowser (e.g. Internet Explorer or Mozilla Firefox). A login window is displayed.
MSX-E1701: Digital I/O Software Watchdog Control of the function „Watchdog“. Refresh / (Re)initialise and start / stop watchdog Counters Status and configuration of the additional counters (compare logic, latch register, frequency measurement and index) can be displayed. Dataserver Network service is a service to supply the clients acquired data via TCP/IP-socket.
Page 42
Changing the IP address via the serial number of the analog input module MSX-E3011: Firstly scan all connected modules by entering as„Your Selection“ the number „0“ Enter 0 The table is valid for all Ethernet I/O modules (MSX-E1701, MSX-E301x and MSX-E351x)
Page 43
MSX-E1701: Digital I/O Software The following screen appears: The screen shows information about all connected modules. ♦ Note the serial number of the selected module (the serial number can be found on the label on the back of your module) You will automatically get into the main menu.
Software MSX-E1701: Digital I/O ♦ Enter the serial number and the new IP address. Firstly a Ping test is realized on the selected IP address to test whether it is occupied or not. Then the new IP address is set.
MSX-E1701: Digital I/O Functions of the module FUNCTIONS OF THE MODULE Block diagram Fig. 8-1: Block diagram Connection examples: Digital I/O 8.2.1 Connection example: Digital inputs (24 V) Fig. 8-2: Connection example: Digital inputs (24 V)
Fig. 8-3: Connection example: Digital outputs (24 V) Function description: Digital outputs and diagnostics The Ethernet I/O module MSX-E1701 has 16 digital inputs and 16 outputs. The outputs work as follows: 1. You can configure a port as outputs by setting the corresponding bits on 1 in the I/O configuration register.
The digital inputs are not concerned by this function. Watchdog The Ethernet I/O module MSX-E1701 has a 16-bit watchdog that can be programmed in three time bases (μs, ms, s). The watchdog is for resetting the digital outputs on 0 V after a certain time (Reload Value).
Appendix MSX-E1701: Digital I/O APPENDIX Glossary Term Description A/D converter =ADC An electronic device that produces a digital output directly proportional to an analog signal output. Baud rate Serial communications data transmission rate expressed in bits per second (b/s). D/A converter...
Page 49
MSX-E1701: Digital I/O Appendix transfer data without electrical continuity, to eliminate high- potential differences and transients. Output voltage The nominal voltage output reading when shaft is rotated to full range, expressed in volts DC /Vo DC). Parameter The parameters of a control comprise all for the control process required numeric values, e.g.
Need help?
Do you have a question about the MSX-E1701 and is the answer not in the manual?