SIRIUS 3RU2/3RB3 overload relays
5.9 Accessories
Step
Operating instruction
3
Attach the former to the release slide.
3
Fit the pushbutton (3SB3000-0EA11) in the
front cover.
4
(Optional) Attach the pushbutton to the
extension plunger (3SX1335).
Disassembly
The figure below shows how to disassemble the holder based on the example of the
3RU21 thermal overload relay:
Table 5- 25
Disassembling the release slide
Step
Operating instruction
1
Press the locking latch down.
2
Tilt the module toward you and take it off the
overload relay.
528
Figure
3
3SX1335
5
3SB3000-0EA11
4
Figure
System Manual, 01/2011, A8E56203870002-03
SIRIUS Innovations