Specification

Inbuilt power flued convection fan heater operated by a simple infra-red remote or by the Rinnai
Wi-Fi app that allows full thermostatic control, as well as other features such as timers. Different
burn media options are available.
Specification summary
Input LPG MJ/h
Input NG MJ/h
Output MJ/h*
Efficiency % (on high)
Heating area m
**
2
Gas type
* Will vary according to gas type and flue configuration
** Will vary depending on geographical location in NZ
Suitability
Ideal for living rooms and open plan areas.
Versatile power flue system makes for easy
installation in almost any living space, including
bedrooms.
The Evolve is ideal for a new build installation
into a false (mock) chimney.
Installation considerations
Room size—smaller rooms will heat up quickly,
and due to the efficiency of the appliance, the
Evolve will turn to a low flame setting once the
set temperature has been reached.
For efficient performance Rinnai recommends
installing the fire as close to the floor as
possible. If the unit is installed higher up the
wall the movement of air from the convection
fan, depending on the room configuration,
could create draughts.
Burn media
Choice of river stones or silky oak log set.
Convection fan
3-speed fan. Heat is distributed from the top of
the appliance.
Data plate
Located inside the appliance, upper right hand
side.
952
1253
10-32
17-32
10-34
17-34
2.4-8.1
4.0-8.4
86
88
65-129
78-134
NG or ULPG
Gas connection
½ " BSP, the gas supply terminates inside the
heater—lower left hand side of the appliance.
Ignition
Continuous spark electronic ignition.
Injector sizes (mm)
952
front
2.1
NG
rear
1.9
front
1.3
ULPG
rear
1.1
Noise level
- 37-45 dB(A)
Power flue
Inner 50 mm, outer 70~80 mm. Appliance must
be installed with a Rinnai flue system.
Power consumption/electrical supply
High
= 90 W
Standby
= <8 W
This heater has a 1.5 m power cord with a
three pin plug supplied. The power cord passes
through a slot in the back left hand corner of
the appliance.
Safety devices
Flame failure sensing system, pressure relief,
overheat safety switch, air temperature sensor,
thermal fuse, overcurrent fuse, and spark
detector.
Temperature control
Operated by using the basic infra-red remote*,
or for more features, such as timers and
thermostatic control, using Rinnai's Wi-Fi
fireplace controller app.
* Temp. sensor is located in the bottom of the remote
Weights
Evolve 952:
Evolve 1253:
Evolve 952/1253 Installation Guide: 13115-F 06-22 | 5
1253
2.8
N/A
1.8
N/A
75 kg
100 kg