Housing Range H98 - Siemens AlgoRex CS1140 Planning

Fire detection system
Hide thumbs Also See for AlgoRex CS1140:
Table of Contents

Advertisement

Housing range H98...

23
Housing range H98...
–> for details, see document 654 / ZH4.2
600
H98G600
H98T000
300
Doors hinged on right
H98G600:
Measurements 600 x 2110 x 300 mm
Material Steel sheet
Color
RAL7035 light gray
Protection category IP40
Mechanical components for H98 housing
Cabinet H98...
H98G600
4161280001
H98T000
4161310001
H98T020
4594150001
H98Z010
4176060001
H15Z200
4597160001
Component carrier
H67E101
5097050001
H67E111
5097180001
H67Z020
4969020001
H47E100
4748850001
H47E110
4761840001
H15Z300
4761970001
H67Z020
4969020001
Options for front installation
H28V000
3795820001
H28V010
3795660001
Options for installation on rear wall
Z3G170
4762230001
G1E010
3842760001
60
Building Technologies
Fire Safety & Security Products
H98G600
Doors can be
locked with KABA
H98T020
lock 1057-25
Doors hinged on left
H98T000/020:
Material Steel sheet
Color
RAL7035 light gray
Protection category IP40
Upright cabinet made from steel sheet with doors and no windows
For large control panels or special applications
Several upright cabinets can be merged to form a group
Doors hinged on right or left
Installation level:
Rear wall –> component carriers H67E101/111 and H47E100/110 or univer-
sal carrier G1E010 –> see page 44
Cover strip H98Z010 per cabinet or group of cabinets
Housing 42HE with base
42HE doors, hinged on right, no windows
42HE doors, hinged on left, no windows
Pair of cover strips for H98G600
Folder pocket for H98T..
Component carrier for H67.. 'complete'
Component carrier for H67... 'Empty'
Shielding hood for H67E...
Component carrier for H47.. 'complete'
Component carrier for H47.. 'Empty'
Battery retaining plate for H47E110
Shielding hood for H67E...
Beams for 19" / 6HE adaptation
Hinge for 19" / 6HE adaptation for G2F031
Installation options for H47E.../H67E...
Universal carrier 3HE
Installation of component carriers H47E.../H67E...
–> for details see page 44
H98Z010
395
H15Z300
Note:
To conform to CE requirements, the H67Z020 cover cap
must be used
Needed per cabinet or group of cabinets
For holding documentation about the system
With cable ducts and battery retaining plate
For non-standard applications
If component carrier is fitted in third-party housing (conforms to
CE)
With cable ducts and battery retaining plate
Without cable ducts and battery retaining plate
For securing to rear wall (profile) –> see page 44
For securing options
H28V000
H28V010
19"
H15Z200
H67Z020
008725_h_en_--
06.2011

Hide quick links:

Advertisement

Table of Contents
loading