FC6x0
Installation
7. Tighten screws.
8. Screw display cover back onto transmitter housing.
9. Using an Allen wrench (size: 3.0), turn the locking screw on display screw plug
12.6.2 Rotating transmitter housing (compact type)
The transmitter housing can be installed in any one of four orientations.
Short-circuit hazard caused by penetrating water
WARNING
Failure of measuring electronics
▶ In order to prevent any water from penetrating the flow meter by way of the cable,
112 / 194
counter-clockwise to tighten.
install the transmitter in a way so that the cable gland is not pointed upward.
A5E52748375-AA, 2023/09
Transmitter installation