Main Cpu (Ci/Cc) Limitation - Siemens AlgoRex CS1140 Planning

Fire detection system
Hide thumbs Also See for AlgoRex CS1140:
Table of Contents

Advertisement

9.1

Main CPU (CI/CC) limitation

select station with
higher RAM
capacity or an
additional station
number of
devices < X ?
no
yes
Building Technologies
Fire Safety & Security Products
The limits within the station types are given
by hard- and software.
Verify all given limits for each required station
by going through this flow chart.
Maximum number of devices per station (RAM)
This limitation is for the CI1142, CC1142, CC1143 station types and depends on how the logical
structure is formed.
The limit values, depending on the estimated average number or ELEMENTS per OBJECT, can be
found in the following diagram.
Max. number of devices
CC1143
CC1142
CI1142 (B3Q661/681/686)
ELEMENTS per OBJECT (average)
Important:
The curve is for the values entered for EP5.
The above limit value must however be corrected downwards for the following configuration.
Number of OBJECTS per SECTION (on average) < 3
Use of ELEMENT texts
Outline quantities of C bus participants
Example:
Average of 3 ELEMENTS per OBJECT
Result: Max. 3000 devices
! Do not go right up to limits!
Include reserve for:
- Changes to project
- System extensions
- Updates for future versions
CI1142 (B3Q460/480/670)
Example:
Average of 5 ELEMENTS per OBJECT
Control panel assignment: 300 devices
Free memory space: 600 devices (-200
reserve) (For use of this value, see page 26
'Max. number of texts')
CI1142:
–15 %
CC1142:
CC1143:
CI1142:
–20 %
CC1142:
–10 %
CC1143:
–10 %
23
008725_h_en_--
06.2011