FIRMWARE
iSBC Controller to Host CPU Messages
B.3.2.2.7
AUTOBAUD COMPLETE.
The Controllers return this message
after they have completed a baud rate scan initiated on a line by a
previous Configure Line command. The host is allowed to issue line
specific commands to the line after it receives this message.
Figure B-33 shows the Autobaud Complete message format.
Message Format
Line Number
Baud Rate
Response
o
07H
1
Line Number
2
Baud Rate
3
4
Reserved
. .
15
I
Reserved
NOTE
Reserved space
should be set to
00 (H) .
The serial channel on which the baud rate has
been recognized.
The baud rate of the serial ch.annel.
None.
Figure B-33.
Autobaud complete Message Format