Cisco Remote PHY Shelf 7200 High Availability Guide for Cisco Remote PHY Shelf 7200 Software 1.1
Configure Port Mapping and Link Redundancy
This section describes how to configure port mapping and link redundancy on the Cisco Remote PHY Shelf
7200.
Map Ports to PHY Devices
Map the eight SFP+ ports with the six PHY devices, by following these steps.
enable
configure terminal
bh-erpd-mapping backhaul <0-7> erpd <0-5>
exit
show running-config bh-erpd-mapping
This is a sample configuration for mapping ports to PHY devices.
Router# enable
Router# configure terminal
Router(config)# bh-erpd-mapping backhaul 0 erpd 0
Router(config)# bh-erpd-mapping backhaul 0 erpd 1
Router(config)# bh-erpd-mapping backhaul 0 erpd 2
Router(config)# bh-erpd-mapping backhaul 0 erpd 3
Router(config)# bh-erpd-mapping backhaul 0 erpd 4
Router(config)# bh-erpd-mapping backhaul 0 erpd 5
Router(config)# exit
Router# show running-config bh-erpd-mapping
Building configuration...
bh-erpd-mapping backhaul 0 erpd 0
bh-erpd-mapping backhaul 0 erpd 1
bh-erpd-mapping backhaul 0 erpd 2
bh-erpd-mapping backhaul 0 erpd 3
bh-erpd-mapping backhaul 0 erpd 4
bh-erpd-mapping backhaul 0 erpd 5
Configure Link Redundancy
To configure link redundancy, follow these steps.
enable
configure terminal
link-redundancy mode [N/A | 6+2 | 4+4]
Modify Port Mapping
Modify port mapping configuration by following these steps.
enable
configure terminal
bh-erpd-mapping backhaul <0-7> erpd <0-5>
Verify Port Mapping
To view the port mapping configuration, follow these steps.
Cisco Remote PHY Shelf 7200 Software Configuration Guide for Cisco Remote PHY Shelf 7200 Software 1.1
Configure Port Mapping and Link Redundancy
49
Need help?
Do you have a question about the Remote PHY Shelf 7200 and is the answer not in the manual?