Fig. 55: Setting the needle thread advancing device (2)
(4) - Stop screw
To set the needle thread advancing device:
1. Loosen the screw (2).
2. Move the needle thread advancing device (3) such that it passes over
3. Tighten the screw (2).
4. Use the stop screw (4) to limit the swivel angle.
71
the clamp and under the sewing foot when completing its forward
motion.
Machine head
Service Instructions 911-211 - 02.0 - 10/2016