Fig. 26: Setting the needle bar height
(1) - Screws
(2) - Needle bar
(3) - Screw
To set the needle bar height:
1. Lock the machine in place at position 1 ( p. 28).
2. Loosen the screws (1).
3. Remove the throat plate (6).
4. Loosen the screw (3) of the needle bar (2).
5. Move the height of the needle bar (2) so that the hook tip (4) is in the
Important
When doing this, take care not to twist the needle. The groove (5) must
face toward the hook.
6. Tighten the screw (3) for the needle bar (2).
7. Place the throat plate (6).
8. Tighten the screws (1).
9. Remove the lock (
Order
Then check the following setting:
• Position of the needle guard ( p. 40)
37
middle of the lower third of the groove on the needle (5).
(4) - Hook tip
(5) - Groove
(6) - Throat plate
p. 29).