Channel-Specific Setting Data - Siemens Sinumerik 840D sl Programming Manual

Iso milling
Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

Data Description
C.4 Channel-specific setting data
C.4

Channel-specific setting data

42110
SD Number
Default setting: 0
Change valid IMMEDIATELY
Data type: DOUBLE
Meaning:
42140
SD Number
Default setting: 0
Change valid IMMEDIATELY
Data type: DWORD
Meaning:
42150
SD Number
Default setting: 0
Change valid IMMEDIATELY
Data type: DOUBLE
Meaning:
42160
SD Number
Default setting: 0
Change valid IMMEDIATELY
Data type: DOUBLE
Meaning:
178
DEFAULT_FEED
Default value for path feed
min. input limit: 0
If no path feedrate is programmed in the part program, then the value stored in
$SC_DEFAULT_FEED is used.
The setting data is evaluated during part program start, giving due consideration to the
feedrate type active at this point of time (refer to $MC_GCODE_RESET_VALUES or
$MC_EXTERN_GCODE_RESET_VALUES).
DEFAULT_SCALE_FACTOR_P
Default scaling factor for address P
min. input limit: -99999999
This machine data is valid in connection with external programming languages. It is effective
for $MN_MM_EXTERN_LANGUAGE = 1.
If no scaling factor P is programmed in the block, then the value from this machine data is
active.
DEFAULT_ROT_FACTOR_R
Default for angle of rotation R
min. input limit: 0
If no factor is programmed for rotation R while selecting the rotation G68, the value from this
setting data is active.
EXTERN_FIXED_FEEDRATE_F1_F9
Fixed feedrates F1 - F9
min. input limit: 0
Fixed feedrate values for the programming of F1 -F9. If the machine data
$MC_FEEDRATE_F!_F9_ON=TRUE is set, the feedrate values from the setting data
$SC_EXTERN_FIXED_FEEDRATE_F1_F9[0] -
$SC_EXTERN_FIXED_FEEDRATE_F1_F9[8] are read and activated as machining feedrate
with the programming of F1 to F9. The rapid traverse feedrate must be entered in
$SC_EXTERN_FIXED_FEEDRATE_F1_F9[0].
Protection level: 7/7
Valid as of software version: 5.2
Protection level: 7/7
Valid as of software version: 5.2
Protection level: 2/7
Valid as of software version:
Protection level: 2/7
Valid as of software version:
Programming Manual, 06/09, 6FC5398-7BP10-1BA0
max. input limit: -
Unit: -
max. input limit: 99999999
Unit: -
max. input limit: 360
Unit: degrees
max. input limit:
Unit: VELO
ISO Milling

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840di slSinumerik 828dSinumerik 802d sl

Table of Contents