Siemens Sinumerik 840D sl Programming Manual page 154

Iso milling
Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

Data Description
C.1 General machine data
10706
MD number
Default setting: 0
Change becomes effective after
Data type: BYTE
Meaning:
MD cannot be changed for SINUMERIK 802D sl.
10715
MD number
Default setting: -1
Changes effective after POWER ON
154
SLASH_MASK
Activation of block skip function
min. input limit: 0
SLASH_MASK == 0
Changing over block skip function is possibly only at end of block after stop.
SLASH_MASK == 1
In SLASH_MASK == 1, the activation of block skip function will also be possible during
program processing.
Notice: The axes are stopped for the duration of the reorganization operation after block skip
function.
SLASH_MASK == 2
Block switchover is possible in each phase.
Notice: The function only becomes effective with a block which comes "later" in the program
run! The function is effective from the next (implicit) stop reset block.
M_NO_FCT_CYCLE[0]
M function number for cycle call
min. input limit: -1
Protection level:
Valid as of software version:
Protection level: 2/7
Programming Manual, 06/09, 6FC5398-7BP10-1BA0
max. input limit: 2
Unit: -
max. input limit: -
Unit: -