24004
Meaning:
MD cannot be changed for SINUMERIK 802D sl.
24006
MD number
Default setting: 0
Changes effective after RESET
Data type: DWORD
Meaning:
MD cannot be changed for SINUMERIK 802D sl.
28082
MD number
Default setting: 0
Changes effective after POWER ON
Data type: DWORD
ISO Milling
Programming Manual, 06/09, 6FC5398-7BP10-1BA0
CHBFRAME_POWERON_MASK
This machine data is used to define whether channel-specific basic frames are reset to the
data management during Power On Reset, i.e. shifts and rotations are set to 0, scaling to 1.
Mirroring is switched off. The individual basic frames can be selected separately.
Bit 0 corresponds to basic frame 0, Bit 1 to basic frame 1 etc.
0: Basic frame is retained at Power ON
1: Basic frame is reset in the data management at Power ON.
CHSFRAME_RESET_MASK
Active system frames after Reset
min. input limit: 0
Bit mask for the reset setting of the channel-specific system frames calculated in the
channel.
Bit
0: System frame for actual value setting and scratching is active after Reset.
1: System frame for external work offset is active after Reset.
2: Reserved, TCARR and PAROT refer to $MC_GCODE_RESET_VALUES[ ].
3: Reserved, TOROT and TORFRAME refer to $MC_GCODE_RESET_VALUES[ ].
4: System frame for workpiece reference point is active after RESET.
5: System frame for cycles is active after Reset.
6: Reserved, reset behavior depends on $MC_RESET_MODE_MASK.
7: System frame $P_ISO1FR (ISO G51.1 Mirror) is active after Reset.
8: System frame $P_ISO2FR (ISO G68 2DROT) is active after Reset.
9: System frame $P_ISO3FR (ISO G68 3DROT) is active after Reset.
10: System frame $P_ISO4FR (ISO G51 Scale) is active after Reset.
corresponds to:
MD28082 $MC_MM_SYSTEM_FRAME_MASK
MM_SYSTEM_FRAME_MASK
System frames (SRAM)
min. input limit: 0
Protection level: 2/7
Valid as of software version: 5.2
Protection level: 2/7
Valid as of software version: 5.2
Data Description
C.2 Channel-specific machine data
max. input limit: 0x7FF
Unit: -
max. input limit: 0x7FF
Unit: -