Motor Connector With Shieldplate - Danaher Motion 601...620 Product Manual

Digital servo amplifier
Table of Contents

Advertisement

Danaher Motion
8.3.4

Motor connector with shieldplate

The motor is connected to the SERVOSTAR 600 by a Power Combicon connector (X9). You can
obtain the connector kit from us (connector, housing, shield plate, rubber bushes, installation mate-
rial, order codes see p.117).
The cable material depends on the motor that is used. Please refer to the installation manual for the
corresponding motor series. Please take note that the connector can accept a maximum conductor
cross-section of 4mm².
®
SERVOSTAR
601...620 Product Manual
07/2007
Electrical Installation
First push the rubber sleeve onto the
cable, and then strip off about 70mm
of the outer covering, without damag-
ing the shielding.
Carefully separate the shielding braid
from the cores.
Twist the shielding braid into a pigtail
and tie it to the sleeve with the wire.
Shorten the brake cores to 55mm
and the power cores to 45mm.
Fold back the overhanging length of
the shielding pigtail to face forwards.
Strip off the ends of the cores for
about 10mm. This length can vary,
depending on the type of bootlace
ferrule that is used.
Apply bootlace ferrules to the con-
ductors. Place the shield plate in the
bottom half of the connector housing.
Place the cable in the strain relief, so
that the folded shielding pigtail lies on
the shield plate, but the tie-wire is not
clamped inside.
Tighten up the screws, without crush-
ing the cable.
Place the connector in the housing.
Take care that the tongue of the
shield plate sits in the PE clamp.
Wire up the connector according to
the wiring diagram on page 50, and
tighten up the clamping screws. Take
care that the insulation is not trapped
underneath. Close the housing.
43