Pic. 97
Service parameters, page 4
Feeding time at 100% power - is the part of the cycle during which pellets will be delivered to
the burner
Protection of burner fan - when this function is activated the boiler checks the functionality of
the pellet fan, shuts it down in the event of a malfunction or clogging and shows an error
Pellet-Fan during ignition - it can only be set by the manufacturer or the service organization it
is the burner fan power that will be during the burning time after ignition
Pellet-Fan during burnout - the fan performance during the burnout phase
Pellet-Fan max. power - only the manufacturer or service organization can set up, the maxi-
mum power of the burner fan
Pellet-Fan min. power - only the manufacturer or service organization can set up, the minimum
power of the burner fan
Size of pellet tank – indicates the size of pellet tank in seconds (during this time the turnstile
feeder will empty the volume of the intermediate pellet tank)
Automatic pellets suction – here you can turn on/turn off automatic pellet suction