Pic. 99
Service parameters, page 6
Upper sensor Limit - ON - is the temperature below which the upper sensor temperature of the
accumulation tank must decrease to switch the automatic boiler on
Middle sensor Limit - OFF - is the temperature which when the middle sensor of the accumula-
tion tank reaches the automatic boiler switches off
Difference boiler temp. Power Regulation- is the temperature of the boiler by which the actu-
al boiler temperature has to decrease compared to the set temperature in order to restart the
exhaust fan
Exhaust temperature start heating - is the flue gas temperature according to which the boiler
evaluates that the wood has been successfully ignited
Exhaust temperature start regulation - is the flue gas temperature, according to which the
boiler evaluates that the boiler has entered the regulation state
Primary-Airflap Max. Open - only the manufacturer or service organization can set up, is the
maximum opening of the primary flap
Secondary-Airflap Max. Open - the maximum opening of the secondary flap
90