Pic. 8
Basic display
1 – Start of boiler, 2 – Boiler temperature, 3 –Flue gas temperature, 4 - Temperature of accumula-
tion tank (optional sensor), 5 - Menu settings of parameters, 6 –General settings, 7 – Error
messages, 8 – Information menu, 9 – Heating circuit, 10 –Outside temperature (optional sensor),
11 – Pellet level in pellet tank (calculated value according to the tank's volume)
The regulation of the WOOD burning is ensured by the Lambda probe together with the con-
trolled rotations of the exhaust fan, controlled inlet of the primary and the secondary air, meas-
uring the temperature of the boiler and flue gas.
The regulation of the PELLETS burning and feeding is ensured by the integrated vacuum feeder
(pellet suction from the main tank into the built-in integrated tank), sensor of the pellet pres-
ence, turnstile auger, ignition coil, photocell, fan with controlled rotations and by the automatic
cleaning.
25