ATTACK WOOD&PELLET 25 Instructions For Use Manual page 92

Table of Contents

Advertisement

Pic. 100
Service parameters, page 7
Secondary- Airflap Min. Open - the minimum opening of the secondary flap
Secondary- Airflap Ignition - the flap position that will be set when the wood is ignited
Secondary- Airflap Pre-Heating - the position of the secondary flap that will be set when the
boiler is in Pre-Heating phase
Ignition max. Time - the time during which the flue gas temperature must reach the flue gas
temperature of the wood igniter. If this temperature is not reached, the boiler will be shut down
and the boiler report a fuel shortage
Exhaust temperature max. power - the flue gas temperature that the boiler will achieve at
maximum wood power
Exhaust temperature min. power - the flue gas temperature that the boiler will achieve at min-
imum wood power
Exhaust temperature Stop - is the flue gas temperature below which, when the flue gas tem-
perature drops, the boiler will report a fuel shortage
Exhaust-Fan Autom. Ignition – fan output during automatic wood ignition with pellets