Parameters description:
Boiler temperature – set temperature which should be reached
Start boiler pump – the temperature when the pump is switched on
Pump delay – the time of pump delay how long the pump will be running after boiler's shut
down
Maximum Power – output of heat pump's in operation (in %)
Exhaust temperature Stop – the temperature below which, when the flue gas temperature
drops, the boiler will report a lack of fuel
Tank capacity - approximate time after which the external pellet tank gets empty
Set night from (hour) - if the heating circuit is connected we determine the hour of night start
when the heating circuit can reduce the temperature
Set night to (hour)- if the heating circuit control is connected we determine the hour of night
termination
After connecting the temperature sensors to the accumulation tank, the boiler can control its
operation according to the temperatures in the accumulation tank. To set the temperature in the
accumulation tank, enter the heating circuit (Pic. 71) and click on the accumulation tank (Pic. 72)