6 LOCATION AND INSTALLATION OF THE BOILER ATTACK
FD SOLID FIRE
Rules and standards
Boilers for solid fuels can be installed only by a company with a valid certificate for installation
and maintenance. Installation must be procceded according to valid standards. Before the instal-
lation of the boiler to an older system of heating the whole system must be cleaned by the com-
pany. The heating system must be filled with watersuitable to the requirements by STN 07
7401:1991 a and its hardness must not exceed required parameters.
Recommended values
Parameter
Hardness
2+
Ca
Concentration of total Fe +
Mn
*) recommended value
a) for heating system
STN EN 12828+A1
STN 06 0830 : 1998
STN 07 7401 : 1992
STN EN 303-5: 2012
b) for chimney
STN 73 4201: 2012
c) according to fire regulations
STN 73 0823: 1984
Notice 95/2004
Possibilities of location
The boiler ATTACK FS is certified for installation in non-residential spaces (cellar, halls, etc.) ac-
cording to Notice 84/1997m) appendix, no. 2, 3, 4, 5, 6, 7, 8, 9, 10 – these appendixes are the part
of this document.
8
Unit
mmol/l
mmol/l
mg/l
Heating systems in buildings. Design for water-based heating systems
Safety devices for central heating and heating of service water
Water and steam for hot water and steam boilers with nominal steam
pressure of up to 8 Mpa
Heating boilers. Part 5: Heating boilers for solid fuels, manually and
automatically stoked, nominal heat output of up to 500 kW. Terminol-
ogy, requirements, testing and marking
Design of chimneys and flue gas ducting
Fire resistance properties of materials. Flammability degree of building
materials
laying down technical conditions, fire safety requirements for the in-
stallation and operation of fuel appliances, electrothermal appliances
and central heating equipment and for the construction and use of
chimneys and flue gas ducts
Value
1
0,3
(0,3)*