4.3.2. Protective class II equipments equipped with mains plug

Insulation resistance between mains part and exposed conductive part of the
tested equipment should be tested.
We advice to use aluminium foil about 200 mm x 100 mm for testing of insulation
resistance on equipments, which have no exposed conductive part. In such case
coat checked part with foil and connect it to one pole of test voltage.
Take into consideration all safety warnings!
Do not touch exposed conductive parts (including foil) while the
measurement is running - risk of electric shock!
Step 1
Press the R
ISO
Either result of last measurement or „---" and set test voltage will be displayed.
Riso 500 V
Step 2
If you need to change test voltage, proceed as follows:
Press the MENU key; the main menu is opened.
Use ▲ and ▼ keys to select submenu „Set-up" and press ENTER.
Copyright © 2004 ILLKO, s.r.o.
SONDE
TEMP.
PRÜFDOSE / TEST SOCKET
R
I
/
ISO LEAK
R
5
I
PE
PE INV.
200mA
ESC 2051
I
U/R
6
PE
DIFF.
10A
DEL
I
7
R
DIFF. INV.
ISO
LOAD
DEL
P
I
8
VA
START
LEAK
SAVE
CAL
ENTER
I
9
MENU
PE
key and release it to select insulation resistance function.
---
SONDE
R
R
I
/
PE
ISO LEAK
R
0
5
PE
200mA
U/R
6
1
PE
10A
2
7
R
ISO
ESC
3
I
8
LEAK
4
I
9
PE
Fig. 6
21
TEMP.
PRÜFDOSE / TEST SOCKET
I
PE INV.
ESC 2051
I
DIFF.
DEL
I
DIFF. INV.
LOAD
DEL
ESC
P
VA
STA RT
SAVE
CAL
ENTER
MENU
ESC 2051

Advertisement

Table of Contents
loading

Table of Contents