B870
1/8" MIN.
1/8" MIN.
SKETCH A
SKETCH C
NEOPRENE HOSE MAY BE
SLIT TO FIT OVER TUBING
SECURE WITH MS3367
CABLE TIES. POSITION SLIT
AWAY FROM WIRES ETC.
SLIT HOSE
CLAMP WIRE BUNDLE
EVERY 2" AT
CROSSOVERS.
PIPER AIRCRAFT
PA - 4 4 - 1 8 0 / 1 8 0 T
AIRPLANE MAINTENANCE MANUAL
Figure 35-4. Oxygen Tubing Installation
2J15
SKETCH B
SKETCH D
GROMMET
CORRECT
2"
1/8" MIN.
INCORRECT
3 5 - 11 - 0 1
Page 35-07
Revised: May 15, 1989