C692
1
2
9
7
3
8
LIFT DETECTOR INSTALLATION DETAIL A
1. CIRCUIT BREAKER (LIFT DETECTOR)
2. CIRCUIT BREAKER (PITOT HEAD)
3. LIFT DETECTOR(S)
4. RESISTOR (5 OHM, 100 W)
5. RELAY
6. PITOT HEAD
7. DEICER BOOT
8. MOUNTING PLATE
Figure 30-16. Heated Pitot and Heated Left Detector Installation (PA-44-180T)
PIPER AIRCRAFT
PA - 4 4 - 1 8 0 / 1 8 0 T
AIRPLANE MAINTENANCE MANUAL
RED AND
WHITE WIRES
(INB'D AND
OUTB'D) TO
H2A4
PURPLE
WIRES (INB'D
AND OUTB'D)
TO H2A5
YELLOW WIRE TO
F1J (INBOARD) FIN
(OUTBOARD)
ORANGE WIRE TO
F1H (INBOARD) F1L
(OUTBOARD)
2F7
REFER TO ELECTRICAL SCHEMATIC - CHAPTER 91
4
5
3
10
13
14
15
9. WING SKIN
10. FIBER WASHER
11. NUT
12. WASHER
13. DOUBLER
14. GASKET
15. SCREW
6
11
12
9
6
3 0 - 9 0 - 0 0
Page 30-51