PIPER AIRCRAFT
PA - 4 4 - 1 8 0 / 1 8 0 T
AIRPLANE MAINTENANCE MANUAL
FUNCTIONAL CHECK OF LIFT DETECTORS.
1. Insert microswitch key under leaf of main gear squat switch.
2. With flaps in 0° and 10° positions, the outboard. lift sensor should activate when lifted.
3. With flaps in 25° and 40° positions, the inboard lift sensor should activate when lifted.
4. After successful completion of functional check, remove microswitch key from main gear squat switch.
— END —
3 0 - 9 1 - 0 0
Page 30-52
Revised: May 15, 1989
2F8