Group F2: Input And Output Parameter - Bosch Rexroth Sytronix FcP 5020 Quick Start Manual

Frequency-controlled pump drive system
Hide thumbs Also See for Rexroth Sytronix FcP 5020:
Table of Contents

Advertisement

Bosch Rexroth AG
FcP 5020 Parameter List

8.3 Group F2: Input and Output Parameter

Code
F2.00 Analog input AI1
F2.01 Analog input AI2
External analog input EAI (-10V...10V,
F2.02
4...20mA)
Pressure command corresponding to
F2.04
10V or 20mA
Pressure command null offset in V or
F2.05
mA
Pressure feedback corresponding to
F2.06
10V or 20mA
Pressure feedback null offset in V or
F2.07
mA
Flow command corresponding to 10V
F2.08
or 20mA
F2.09 Flow command null offset in V or mA
F2.10 Pressure sensor type
56/75
Name
0: No function assigned from
ASF
1: Pressure command
2: Pressure feedback
3: Flow command
0.1...1,000.0 bar
0.0...5.0 V, mA
0.1...1,000.0 bar
0.0...5.0 V, mA
1...5,000 rpm
0.0...5.0 V, mA
0: Others
1: HM20-2X/10-C
2: HM20-2X/50-C
3: HM20-2X/100-C
4: HM20-2X/160-C
5: HM20-2X/250-C
6: HM20-2X/315-C
7: HM20-2X/400-C
8: HM20-2X/630-C
9: Reserved
10: Reserved
11: HM20-2X/10-H
12: HM20-2X/50-H
13: HM20-2X/100-H
14: HM20-2X/160-H
15: HM20-2X/250-H
16: HM20-2X/315-H
17: HM20-2X/400-H
18: HM20-2X/630-H
Setting range
Default Min.
100.0
DOK-RCON03-FCP5020****-QU02-EN-P
FcP 5020
Attri.
0
-
Stop
2
-
Stop
0
-
Stop
10.0
0.1
Stop
0.0
0.1
Stop
0.1
Stop
4.0
0.1
Stop
(mA)
400
1
Stop
0.0
0.1
Stop
3
-
Stop

Advertisement