Bosch Rexroth Sytronix FcP 5020 Quick Start Manual page 22

Frequency-controlled pump drive system
Hide thumbs Also See for Rexroth Sytronix FcP 5020:
Table of Contents

Advertisement

Bosch Rexroth AG
Block Diagram of Main Functions
Code
Name
F1.11 Flow command source
F1.12 Flow command digital setting 0...5,000 rpm
F2.00 Analog input AI1
F2.01 Analog input AI2
External analog input EAI
F2.02
(-10V...10V, 4...20mA)
Flow command correspond-
F2.08
ing to 10V or 20mA
Flow command null offset in V
F2.09
or mA
F3.03 Filter time for flow command 0...999 ms
Protection function control
F4.00
word
F4.20 p/Q command soft start delay 0.0...1,000.0 s
F4.23 Minimum flow command limit 0...[F4.24] rpm
F4.24 Maximum flow command limit [F4.23]...5,000 rpm
Tab. 7-1: Parameter list of flow command processing
F2.08, F2.09: Scaling for flow command
Fig. 7-3:
Flow command scaling
18/75
Setting range
0: Depend on the value of
F1.12
1: Analog input (positive /
negative)
2: Communication
0: No function assigned from
ASF
1: Pressure command
2: Pressure feedback
3: Flow command
1...5,000 rpm
0.0...5.0 V, mA
0...15
Bit0: Pressure sensor failure
(PSF)
Bit1: Actual pressure moni-
toring
Bit2: p/Q max. command lim-
it
Bit3: Oil changing detection
Default
Min.
0
-
400
1
0
-
2
-
0
-
400
1
0.0
0.1
4
1
0
-
0.0
0.1
200
1
3,000
1
DOK-RCON03-FCP5020****-QU02-EN-P
FcP 5020
Attri.
Stop
Run
Stop
Stop
Stop
Stop
Stop
Run
Run
Stop
Stop
Stop

Advertisement

Table of Contents
loading