Initial Start Up - Bosch Rexroth Sytronix FcP 5020 Quick Start Manual

Frequency-controlled pump drive system
Hide thumbs Also See for Rexroth Sytronix FcP 5020:
Table of Contents

Advertisement

FcP 5020

5 Initial Start Up

After the electric hydraulic system has been correctly assembled, users can take
following steps for initial start up.
1. Select pressure sensor via F2.10 (for option ''0: Others", please set F2.06,
F2.07 manually).
2. Choose motor parameter via F1.15 and F1.16 for Rexroth MOT-FC_HOY mo-
tor. For other motors set F1.15 to 0, and set motor parameter in EFC pa-
rameter group C, please reference EFC 5610 quick start guide (material
number is R912005856).
3. Set pressure command via F1.03...F1.08 and flow command via F1.11,
F1.12.
4. Run the FcP system.
The pressure command F1.05 and flow command F.12 default val-
ues are set to low values to prevent potential machine damage
caused by improper use during initial start up.
For CytroPac application, set F1.20 according to different Cytro-
Pac type.
Code
Name
F1.03 Pressure command source
F1.04 Pressure command selection
Pressure command digital set-
F1.05
ting 0
Pressure command digital set-
F1.06
ting 1
Pressure command digital set-
F1.07
ting 2
DOK-RCON03-FCP5020****-QU02-EN-P
Setting range
0: Depend on the value of
F1.04
1: Select by digital input (F1.04
shows status)
2: Analog input
3: Communication
0: Pressure command digital
setting 0
1: Pressure command digital
setting 1
2: Pressure command digital
setting 2
3: Pressure command digital
setting 3
0.0...1,000.0 bar
0.0...1,000.0 bar
0.0...1,000.0 bar
Bosch Rexroth AG
Initial Start Up
Default
Min.
Attri.
0
-
Stop
0
-
Run
10.0
0.1
Run
10.0
0.1
Run
10.0
0.1
Run
7/75

Advertisement

Table of Contents
loading

Table of Contents