FcP 5020 Parameter List

8.5 Group F4: System Protection and Pump Function Parameter

Code
Name
F4.00 Protection function control word
F4.03 Pump function control word
Pressure sensor failure detection
F4.06
threshold 1 (negative direction)
Pressure sensor failure detection
F4.07
time 1 (negative direction)
Pressure sensor failure detection
F4.08
threshold 2 (positive direction)
Pressure sensor failure detection
F4.09
time 2 (positive direction)
F4.10 Pressure detection threshold
F4.11 Pressure detection period
Maximum system pressure (warn-
F4.15
ing)
F4.16 Maximum pump pressure (error) [F4.15]...4,000.0 bar
F4.20 p/Q command soft start delay
F4.21 Minimum pressure command limit 0.0...[F4.22] bar
Maximum pressure command lim-
F4.22
it
F4.23 Minimum flow command limit
F4.24 Maximum flow command limit
60/75
Setting range
0...15
Bit0: Pressure sensor failure
(PSF)
Bit1: Actual pressure moni-
toring
Bit2: p/Q max. command lim-
it
Bit 3: Oil changing detection
0...31
Bit0: Pump power limit
Bit1: Pump thermal protec-
tion
Bit2: Switch master to slave
Bit3: Two points / double
pump
Bit4: Pressure drop / over-
shoot compensation
-5,000...0 rpm
0.1...100.0 s
0...5,000 rpm
0.1...100.0 s
1.0...1,000.0 bar
0.1...100.0 s
0.0...[F4.16] bar
0.0...1,000.0 s
[F4.21]...1,000.0 bar
0...[F4.24] rpm
[F4.23]...5,000 rpm
DOK-RCON03-FCP5020****-QU02-EN-P
FcP 5020
Default
Min.
Attri.
0
-
Run
0
-
Run
-1
1
Stop
10.0
0.1
Stop
200
1
Stop
10.0
0.1
Stop
5.0
0.1
Stop
1.0
0.1
Stop
500.0
0.1
Stop
1,000.0
0.1
Stop
0.0
0.1
Stop
5.0
0.1
Stop
250.0
0.1
Stop
200
1
Stop
3,000
1
Stop

Advertisement