Maximum Permissible Exhaust Temperature Exceeded; Ems Voltage Supply Below The Minimum Required Level; The Sprag Clutch Decouples Not From The Starter; January 01/2012 - Rotax 912 i series Operator's Manual

Hide thumbs Also See for 912 i series:
Table of Contents

Advertisement

4.14) Maximum permissible exhaust temperature exceeded

Exceeded ex-
haust temperature

4.15) EMS voltage supply below the minimum required level

Voltage supply be-
low level

4.16) The sprag clutch decouples not from the starter

Spag clutch is per-
manently in en-
gagement position
Effectivity: 912 i Series
OM Edition 1/Rev. 0
NOTICE
WARNUNG
-
Check the exhaust temperature.
-
Oil and coolant limits must not be exceeded.
-
A maintenance inspection should be carried out.
-
Limited flight operation is possible if the voltage (alternator A
or B) is OK here.
-
Proceed according to section: „Failure of the EMS power sup-
ply" if this shows no effect.
NOTICE
WARNUNG
-
A maintenance inspection should be carried out.
NOTICE
WARNUNG
-
Move the throttle lever to the idle position.
Set the EMS main switches to "OFF".
-
Switch both LANE select switches to "OFF".
-
-
A maintenance inspection should be carried out.
BRP-Powertrain
Reduce engine power setting to the minimum
necessary and carry out precautionary land-
ing.
Reduce engine power setting to the minimum
necessary and carry out precautionary land-
ing.
Switch the engine "OFF". Risk of fire and dan-
ger of the electric starter overheating.
page 4-6