Effectivity: 912 i Series
Edition 2 / Rev. 0
Only switch on one fuel pump when starting the engine. Switching
on both fuel pumps can lead to a bad start behavior.
Step
Designation
5
Lane select Switch A.
Lane select Switch B.
6
Start Power Switch.
7
Check of Warning Lamps.
When the voltage supply is switched on, both lamps are automati-
cally subject to a function test. Both lamps illuminate for around 3
seconds and then extinguish.If one of the two warning lamps start to
flash, fail to illuminate, or still illuminates after a few seconds, then
this indicates an anomaly operation.
Step
Designation
8
Engine instruments.
9
Throttle valve.
For more and detailed information on the throttle opening during en-
gine start up see the diagram.
Step
Designation
10
Starter button.
BRP-Rotax
ATTENTION
Procedure
ON
Activate Start Power
Switch during steps 7, 8, 9
and 10.
Check if Warning Lamps
illuminate and extinguish
after around 3 seconds.
ATTENTION
Procedure
Check if fuel pressure
has reached its fuel pres-
sure of 3 bar (43.5 psi).
Put throttle between 1 to 2
cm throttle opening (cor-
relates with 55%-65%
throttle valve opening).
ATTENTION
Procedure
Press until the engine runs
and release after engine
has reached 1500 rpm or
more (stable engine run).
Page 3-7
January 01 2019